Available Configurations
See table 1
End Connections
Inlet: 1/4-inch 18 NPT femaleOutlet: Types 670, 672, and 675—1/4-inch 18 NPT female; Type 671—3/8-inch 18 NPT female; Type 674—1/4-inch 18 NPT female
Maximum Allowable Inlet Pressure
Without Changeover Valve: 250 psig (17 bar)With Changeover Valve: 50 psig (3.4 bar)
Maximum Outlet Pressure and Emergency Outlet Pressure
Outlet Pressure Ranges
Types 670 and 675(1): ■ 0.2 to 1.2 bar (3 to 18 psig); ■ 0.3 to 2.1 bar (5 to 30 psig); ■ 2.1 to 3.4 bar (30 to 50 psig); and ■ 2.4 to 5.5 bar (35 to 80 psig) except 2.4 to 3.4 bar (35 to 50 psig) with changeover valveType 671: ■ 0 to 0.07 bar (0 to 1 psig); ■ 0 to 0.34 bar (0 to 5 psig)Type 674: ■ 0.7 to 5.2 bar (10 to 75 psig); ■ 3.4 to 10.3 bar (50 to 150 psig); ■ 6.9 to 15.5 bar (100 to 225 psig)
Pressure Registration
Internal
Construction Materials
Panel Tubing: ■ Copper, ■ PVC-coated copper, ■ aluminum, or ■ S31600 (316 stainless steel)Regulator Body:Types 670 and 675: Die-cast aluminumType 671: Die-cast zincType 674: BrassRegulator Spring Case:Types 670 and 675: Die-cast zinc/stainless steelType 671: Die-cast zincType 674: Forged brass or steelPanel:Types 670, 670F, and 671: ZincTypes 670FG, 670G, 670FGV, and 670GV: SteelHandwheel: Die-cast aluminum Other Regulator Parts:Diaphragm: NitrileValve Disk: NitrileDiaphragm Plate: Plated steelSpring: Plated steelFilter Cartridge (Type 67AFR Regulator Only): Cellulose (standard), stainless steel, or brass
Material Temperature Capabilities
-29 to 71°C (-20 to 160°F)
Pressure Gauges
Connection: 1/8-inch NPT male fitting on back of caseRanges: Standard ranges shown in table 2 with other ranges available upon requestFace Colors: White with black numeralsCase Color: BlackGauge Identification: White engraving on black laminated plastic plate below gauge indicates units and function. Up to 16 characters per line, 3 lines, are available
Regulator Port Diameters
Types 670 and 675: 3.2 mm (0.125 inch)Type 671: Standard--1.8 mm (0.073 inch); Optional--2.4 mm (0.094 inch)Type 674: 2 mm (0.078 inch);
Operating Influences(2)
670 Series: As shown in figure 4, output pressure changes less than 0.34 bar (5 psig) when the input pressure changes between 1.4 and 9.7 bar (20 and 140 psig)Type 671: As shown in figure 5, output pressure changes less than 2.5 mbar (1 inch w.c.) when the input pressure changes between 1/4 amd 0/7 bar (20 and 140 psig)
Regulator Flow Capacity
See appropriate pressure regulator bulletin
Internal Relief for Pressure Regulators
Adequate for relieving only minor buildup situations. Refer to the appropriate pressure regulator bulletin to determine if external relief is required.
Close Section Above
Note: Fisher does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Fisher product remains solely with the purchaser and end-user.
Dimensions for installation clearances are shown in figures 6 and 7 and table 3.