670 Loading Regulators Tables Figures Print Version Collapse Expand
 
670 Series Panel-Mounted Loading Regulators

670 Loading Regulators Description The Types 670, 671, 674, and 675 panel-mounted loading regulators (figures 1, 2, 3, 6, and 7) are compact, rugged units used primarily for manually loading pressure-balanced gas regulators and providing manual control for diaphragm actuator control valves. Applications include remote control of gas pressure to burners in refineries, power plants, and various process furnaces. The Types 670 and 675 units use the Type 67R or 67AFR pressure regulator, the Type 671 unit uses the Type 912 pressure regulator, and the Type 674 unit uses the Type 1301F pressure regulator.
The Type 672 unit is a loading panel and does not use regulators. The Type 672 panel has one gauge and a changeover valve.
Three basic panels are available within the product line as shown in figure 1, 6, and 7, each having one pressure regulator connected to one or two gauges or two gauges and a changeover valve. A single gauge typically shows loading pressure to the control valve. With two gauges, one gauge shows the loading pressure and the other gauge can be connected to show downstream control pressure or any other pressure up to 20.6 bar (300 psig). Manual backup of pneumatic controllers can be handled with those 670 Series units having a changeover valve. With it the operator selects either the automatic controller output (displayed on one gauge) or the manual loader output (displayed on the other gauge and adjusted by the handwheel) as the signal to the control valve actuator.
       Close Section Above

Specifications

Available Configurations

See table 1

End Connections

Inlet: 1/4-inch 18 NPT female
Outlet: Types 670, 672, and 675—1/4-inch 18 NPT female; Type 671—3/8-inch 18 NPT female; Type 674—1/4-inch 18 NPT female

Maximum Allowable Inlet Pressure

Without Changeover Valve: 250 psig (17 bar)
With Changeover Valve: 50 psig (3.4 bar)

Maximum Outlet Pressure and Emergency Outlet Pressure

See table 1

Outlet Pressure Ranges

Types 670 and 675(1): ■ 0.2 to 1.2 bar (3 to 18 psig); ■  0.3 to 2.1 bar (5 to 30 psig); ■  2.1 to 3.4 bar (30 to 50 psig); and ■  2.4 to 5.5 bar (35 to 80 psig) except 2.4 to 3.4 bar (35 to 50 psig) with changeover valve
Type 671: ■  0 to 0.07 bar (0 to 1 psig); ■  0 to 0.34 bar (0 to 5 psig)
Type 674: ■  0.7 to 5.2 bar (10 to 75 psig); ■  3.4 to 10.3 bar (50 to 150 psig); ■  6.9 to 15.5 bar (100 to 225 psig)

Pressure Registration

Internal

Construction Materials

Panel Tubing: ■ Copper, ■ PVC-coated copper, ■ aluminum, or ■ S31600 (316 stainless steel)
Regulator Body:
Types 670 and 675: Die-cast aluminum
Type 671: Die-cast zinc
Type 674: Brass
Regulator Spring Case:
Types 670 and 675: Die-cast zinc/stainless steel
Type 671: Die-cast zinc
Type 674: Forged brass or steel
Panel:
Types 670, 670F, and 671: Zinc
Types 670FG, 670G, 670FGV, and 670GV: Steel
Handwheel: Die-cast aluminum
Other Regulator Parts:
Diaphragm: Nitrile
Valve Disk: Nitrile
Diaphragm Plate: Plated steel
Spring: Plated steel
Filter Cartridge (Type 67AFR Regulator Only): Cellulose (standard), stainless steel, or brass

Material Temperature Capabilities

-29 to 71°C (-20 to 160°F)

Pressure Gauges

Connection: 1/8-inch NPT male fitting on back of case
Ranges: Standard ranges shown in table 2 with other ranges available upon request
Face Colors: White with black numerals
Case Color: Black
Gauge Identification: White engraving on black laminated plastic plate below gauge indicates units and function. Up to 16 characters per line, 3 lines, are available

Regulator Port Diameters

Types 670 and 675: 3.2 mm (0.125 inch)
Type 671: Standard--1.8 mm (0.073 inch);
Optional--2.4 mm (0.094 inch)
Type 674: 2 mm (0.078 inch);

Operating Influences(2)

670 Series: As shown in figure 4, output pressure changes less than 0.34 bar (5 psig) when the input pressure changes between 1.4 and 9.7 bar (20 and 140 psig)
Type 671: As shown in figure 5, output pressure changes less than 2.5 mbar (1 inch w.c.) when the input pressure changes between 1/4 amd 0/7 bar (20 and 140 psig)

Regulator Flow Capacity

See appropriate pressure regulator bulletin

Internal Relief for Pressure Regulators

Adequate for relieving only minor buildup situations. Refer to the appropriate pressure regulator bulletin to determine if external relief is required.


1. These pressure ranges are recommended, but all springs used in the Type 67R or 67AFR regulators can be adjusted down to 0 bar or 0 psig.
2. Defined in ISA Standard S51.1-1979.
       Close Section Above

Features

  • Control Flexibility—With a changeover valve, the operator can deliver pressure to the control valve from the manual loader, a controller, or bypass the panel completely.
  • Gauge Identification—Big, clear, white-on-black labels (see figure 1) show gauge function and units at a glance.
  • Convenient Fingertip Control—Turn the panel-mounted handwheel clockwise to increase or counter-clockwise to decrease pressure to the control valve while watching the high visibility black-on-white gauges.
  • Easy Connections—Unit comes with all the hardware necessary to connect the loading pressure gauge to the pressure regulator.
  • Versatility—Pressure regulators are suitable for a variety of gaseous fluids including natural gas, propane, and air.
  • Compact Size—The slim profiles of the regulators are ideal for installations where space behind the panel is limited.

       Close Section Above

Installation

Note: Fisher does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Fisher product remains solely with the purchaser and end-user.

Dimensions for installation clearances are shown in figures 6 and 7 and table 3.

       Close Section Above

Ordering Information Carefully review the specification table and indicate your choice wherever a selection is offered, including:
1. Range of pressure gauge(s)
2. Whether a changeover valve is desired (670 Series only)
       Close Section Above


TABLES Table 1. Available Configurations
Type
Number
Number
of
Gauges
Description Regulator
Type
Number
Maximum Inlet Pressure Maximum Outlet Pressure Maximum Emergency Outlet Pressure
670 1 Basic 1-gauge panel 67R 17.2 Bar
(250 Psig)
6.9 Bar
(100 Psig)
7.6 Bar
(110 Psig)
670F 1 1-gauge panel; regulator has filter 67AFR
670FG 2 2-gauge panel; regulator has filter 67AFR
670FGV 2 2-gauge panel with 3-way changeover valve; regulator has filter 67AFR 3.5 Bar
(50 psig)
3.5 Bar
(50 Psig)
3.8 Bar
(55 Psig)
670G 2 Basic 2-gauge panel 67R 17.2 Bar
(250 psig)
6.9 Bar
(100 Psig)
7.6 Bar
(110 Psig)
670GV 2 2-gauge panel with 3-way or
4-way changeover valve
67R 3.5 Bar
(50 Psig)
3.5 Bar
(50 Psig)
3.8 Bar
(55 Psig)
671 1 Basic 1-gauge panel 912N 17.2 Bar
(250 Psig)
0.4 Bar
(5 Psig)
0.7 Bar
(10 Psig)
672V 1 Basic 1-gauge panel with 3-way
changeover valve
--- - - - - - - - - -
674G 2 Basic 2-gauge panel 1301F 414 Bar
(6000 Psig)
15.5 Bar
(225 Psig)
17.2 Bar
(250 Psig)
675G 2 Basic 2-gauge panel 67R 17.2 Bar
(250 Pisg)
6.9 Bar
(100 Psig)
7.6 Bar
(110 Psig)

       Close Section Above

Table 2. Pressure Gauge Ranges - Triple Scale
Bar Psig Pa
0 to 0.6
0 to 2
0 to 4
0 to 11
0 to 20
0 to 10
0 to 30
0 to 60
0 to 160
0 to 300
0 to 0.6k
0 to 0.2M
0 to 0.4M
0 to 1.1M
0 to 2M

       Close Section Above

Table 3. Dimensions
TYPE
NUMBER
DIMENSION
A B C D E F(1) Panel Cutout
mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch
670
670F
670G
670FG
670GV
670FGV
671
102
102
203
203
203
203
102
4.00
4.00
8.00
8.00
8.00
8.00
4.00
71
71
171
171
171
171
71
2.80
2.80
6.80
6.80
6.80
6.80
2.80
71
69
61
61
61
61
66
2.80
2.70
2.40
2.40
2.40
2.40
2.60
51
51
61
61
61
61
53
2.00
2.00
2.40
2.40
2.40
2.40
2.10
19
---
70
---
19
---
---
0.75
---
2.75
---
0.75
---
---
---
150
---
181
---
181
---
---
6.00
---
7.10
---
7.10
---
83 x 184
83 x 184
184 x 184
184 x 184
184 x 184
184 x 184
83 x 184
3.25 x 7.25
3.25 x 7.25
7.25 x 7.25
7.25 x 7.25
7.25 x 7.25
7.25 x 7.25
3.25 x 7.25
1. Dimension F refers to the depth to which those regulators with filters extend behind the panel.

       Close Section Above

       Close Section Above



62.3:670
September 2002
©Fisher Controls International, Inc. 1992, 2002; All Rights Reserved Printed in USA